Super Anchor Safety RLT-36" HDG Riser w/steel loop top, Schedule 80, field weld 1048-WG

$375.00
SKU SAS1048-WG
This Pre-Engineered permanent flat/low-slope roof anchor is specified for use as a single user fall protection anchor point, a window-washing suspension/tie-back anchor point, as a horizontal lifeline intermediate anchor or as an intermediate anchor with pass-thru top. The anchors are designed for installation in the field by welding the riser to structure. Backed by full 3rd party engineering.

CRA Weld-On Discussion: The weld on risers have been reviewed by a 3rd party engineering firm for an ultimate capacity of 5,000 lbs. in any direction. The typical part numbers in the report are a 3-4.5 inch outside diameter pipe with varying thickness (Sch. 40 and Sch. 80 pipe) with loop tops welded to the top of the anchor riser. It is anticipated that these anchors will be welded at the base of the pipe to an existing steel structure without causing large deformations of high stresses in the existing structure. The review of the existing structure is the responsibility of the contractor.

Weld specifications:

    CRA risers 24” and less: field welds shall be 3/8” fillet welds all around the riser. The steel thickness at the weld location shall be at least 3/8” thick. Electrodes for all field welds shall be Class E70XX. The steel framing shall be able to support a point torsion load of 5,000 pounds times the riser height. The torsional stiffness of the existing structure shall be large enough to prevent the rotation of the structure-anchor group for twisting more than 10 degrees.
    CRA risers 24” and taller: field welds shall be ½” fillet welds all around the riser. The steel thickness at the weld location shall be at least ½” thick. Electrodes for all field welds shall be Class E70XX. The steel framing shall be able to support a point torsion load of 5,000 pounds times the riser height. The torsional stiffness of the existing structure shall be large enough to prevent the rotation of the structure-anchor group for twisting more than 10 degrees.

CRA Weld-On Riser Overview:

    DECKING ATTACHMENTS: Structural Steel
    ATTACHMENT HARDWARE: Field Welds
    ROOFING MATERIAL: Built-Up Roofing, Spray-On Roofing, Modified Bitumen Roofing, Green Roofs, PVC, EPDM, TPO, Asphalt Shingle Roofing, Corrugated and Standing Seam Metal Roofs
    FLASHING: provided by the roofing contractor or built on site and flashed as per standard procedures for a 3” or 4.5” OD pipe. A factory supplied 35-year EPDM flashing for metal roof applications is available.
    FALL PROTECTION CONFIGURATIONS:
  • Stand Alone Anchor/Tie-Back Anchors for Fall Protection
  • Roof Perimeter Cable Pass-Through systems
  • Roof Centerline Cable Pass-Through systems
  • Roof Perimeter Based Window Washing Tie-Back Anchors
  • Roof Centerline Based Window Washing Tie-Back Anchors

Each CRA anchor comes with a 4-page, comprehensive Instruction/Specification Manual to cover most installation options. See the Engineering tab for comprehensive design/testing/engineering documents.

  • Certified for Fall Protection and Window Washing
  • ASTM 123 Hot Dip Galvanized Coating
  • 5,000-pound Minimum Strength
  • Stand Alone Anchors or Use in Horizontal Lifeline System up to 130’
  • Available in 304/316 Stainless Steel
  • Individual Serial Number Tag Riveted onto Riser
  • Large Inventory in Stock
  • Pre-Engineered Design for Easy Compliance

Window Washing Suspension: Roof and Wall Safety/Tie-Back Anchors for window washing suspension require special consideration. North America safety standards require a building to have certified anchorages capable of supporting the necessary loads before any worker suspends from the anchor. Our anchors can help you provide compliance with OSHA, ANSI and IWCA I-14.1 standards for window cleaning or any other job requiring suspension over the edge of the building.

Window Washing suspension requires 2 anchors for the worker to tie off to – one anchor supports the workers equipment and one anchor is used for the safety lifeline or fall arrest equipment. Our pre-engineered anchors give you the compliance that you need at an affordable cost. Our unique line of anchors can be mounted to roof decking, concrete curbs/beams/walls, steel beams as well as other structures capable of supporting the intended loads. The CRA’s for window washing are designed for a 5,000-pound ultimate load, a 2,500-pound test load and a 1,250-pound allowable load. Parapet walls must be capable of supporting the intended loads, too.

With over 25 years’ experience, super Anchor Safety is the industry leader for commercial Roof anchors and horizontal lifeline systems. Used primarily on low slope applications, anchors can be custom fabricated for attachment to any type of structural support and to any architectural requirement. Our time-tested anchor designs are cost effective, easy to install, low maintenance and feature state of the art precast loop tops and pass through connector fixtures. We stock all the horizontal lifeline accessories needed for your project including IWCA window washing and Cal-OSHA compliant roof anchors. We can also supply 100% USA Manufactured/Certified anchors. Our simple design backed up with a full regimen of engineering documents is a cost effective, easy to install, low maintenance permanent fall protection fixture.